This standard was last reviewed and confirmed in 2021.
Therefore this version remains current.
Abstract
PreviewThe principle of the method specified is dissolving a test portion in dimethylformamide and injecting a small volume of the solution into a gas chromatograph equipped with flame ionization detector to separate and detect the volatile components. The solvent contains a known amount of propionitrile or acetonitrile as an internal standard for quantitative evaluation. With this method, a lower detection limit of the order of 3 ppm of acrylonitrile in the copolymer may be expected. To obtain a lower detection limit of the order of 0,3 ppm to 0,4 ppm, an alternative method is specified in annex A.
-
Status: PublishedPublication date: 1994-08
-
Edition: 2Number of pages: 8
-
- ICS :
- 83.080.20 Thermoplastic materials
Buy this standard
en
Format | Language | |
---|---|---|
std 1 61 | ||
std 2 61 | Paper |
- CHF61
Life cycle
-
Previously
WithdrawnISO 4581:1987
-
Now
Got a question?
Check out our FAQs
Customer care
+41 22 749 08 88
Opening hours:
Monday to Friday - 09:00-12:00, 14:00-17:00 (UTC+1)